4.0 Hardware Installation
4.7.11 ZONE 4 LINE OUT output
The ZONE 4 LINE OUT jack provides a line-level output that
duplicates the program material on LINE 4. This may be used to
feed another Bose
®
amplifier installed for a large zone. The 12V
control output is used to connect to Bose amplifier sequence
inputs.
4.8 AC power connections
Installers Note: The fuse box configuration must be coor-
dinated with the 70/100V OUTPUT VOLTAGE setting: 70V
should be selected for 100-120VAC; 100V should be selected
for 220-240VAC.
Fuse box configuration
The fuse box is configured at the factory according to the specifi-
cations of your order. Should you need to replace the fuse, follow
these steps:
1. Using a thin screwdriver blade, open the fuse box. Pull out
the drawer and remove the fuse.
2. Insert a new fuse of the same type and rating into the fuse
box drawer.
3. Slide the fuse box drawer back into the fuse box.
AC power cord receptacle
Insert the proper power cord for the voltage used in your region.
RCA
T
S
T
S
12V
XLR
1
3
1
2
3
12V
Phone
Plug
(Balanced)
T R S
T
R
S
12V
Phone
Plug
(Unbalanced)
TS
T
S
12V
Control Signal
12V
Source Connector
E-4 ZONE 4 LINE OUT
Bose 1600, 1800 or M2150 Amplifier
2
Voltage
selection
indicator
Fuse
Power cord
receptacle