Bose FreeSpace DS 16SE User Manual Page 6

  • Download
  • Add to my manuals
  • Print
  • Page
    / 8
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 5
6
pro.Bose.com
OF 8
TECHNICAL DATA SHEET
FreeSpace
®
DS 16S/DS 16SE
Loudspeakers
Engineers’ and Architects’
Specifications
Each loudspeaker shall be a 16-watt, ported
loudspeaker utilizing one 2.25" (57mm)
full-range driver for installation on walls or
other flat, solid surfaces.
The driver shall have a nominal rated impedance
of 8 ohms and shall be wired in parallel with a
line voltage matching (step-down) transformer
with a level selector appropriate for various
output taps. The loudspeaker input connections
will allow for direct connection to either 70V,
100V or low-impedance amplifiers.
Exposed cosmetic surfaces of the loudspeakers
shall be paintable, and the acoustically transparent
grille component shall be formed of powder-
coated steel.
Each loudspeaker shall have a bandwidth of
90 Hz – 16 kHz and a maximum acoustic output
of 96 dB-SPL referenced to a full-bandwidth
pink noise input at 1 meter at the loudspeaker’s
rated power. The input connection shall consist
of a three-position barrier connector on the
included mounting bracket. Each loudspeaker
shall be wired to the mounting bracket via a
four-pin, pre-wired connector.
Power settings available shall be: 1W, 2W, 4W,
8W, 16W @ 70V; 2W, 4W, 8W, 16W @ 100V; and
16W @ 8Ω (when referenced to IEC noise for
100 hours). The nominal dispersion shall be
170°H x 160°V at -6 dB (average 1 – 4 kHz).
When used with optional junction boxes, which
include a ceramic connector and a thermal fuse,
the loudspeakers shall meet numerous standards
for combination music and evacuation systems
around the world.
The loudspeakers shall be the Bose
®
FreeSpace
®
DS 16S and DS 16SE loudspeakers.
Safety and Regulatory Compliance
The FreeSpace DS 16S and DS 16SE have passed
extensive testing and comply with the following
specifications and uses:
Listed to ANSI/UL 1480-2005
Fire Protective Signaling Use – UL Category
UUMW, File Number S 3241.
Control Number 42S9 when installed with a
junction box (on-wall or in-wall).
Not for use with DC-supervised systems.
General-Purpose Use – UL Category UEAY,
File Number S 5591 Control Number 3N89.
The DS 16SE is suitable for use outdoors in
wet locations.
The DS 16S is suitable for use indoors in
damp locations.
Suitable for installation using Class 1, Class 2
or Class 3 wiring methods in accordance with
NFPA 70, National Electric Code, 2002,
Article 640.
Suitable for use with fire alarm circuit wiring
methods in accordance with NFPA 70,
National Electric Code, 2002, Article 760.
The DS 16S and DS 16SE also have been
designed to the requirements defined in the
following European regulatory specification
for combination systems:
British Standard Code of Practice BS 5839,
Part 8.
Tested to IEC60268-5.
Limited Warranty
The FreeSpace DS 16S and DS 16SE loudspeakers
are covered by a five-year transferable limited
warranty.