Software User Guide
Chapter 5: Program user controls: CC-64 and CC-16
107
Figure 5.28 - Volume properties dialog box
Specify the Maximum volume, Minimum volume and Step size in decibel
values in the boxes to the left. Step size is the incremental change in
decibels each time the “+” or “-” volume button is pushed. The numbers to
the right indicate what is displayed on the CC-16 LCD display. As you
change the Max, Min and Step values in the boxes on the left, the step
value is automatically updated on the right. The Max display value will
always be 99, and the Min display value will always be 1 (or 0 if you set
the Min to -infinite decibels). After setting the volume properties, use the
volume control buttons on the Smart Simulator to verify what the user will
see in the LCD display.
Locking the CC-16
When the CC-16 is locked, the select and volume control buttons are
disabled. You might use this feature if, for example, you have multiple
CC-16s in your design, and need to disable one or more for a certain
configuration. Like the CC-64, The lock/unlock status of a CC-16 must be
stored in a parameter set. When this parameter set is invoked, the CC-16
is locked or unlocked. To store the lock/unlock status in a parameter set,
first set the lock button on the CC-16 Smart Simulator to the locked or
unlocked state, then drag the CC-16 from Project View into a parameter
set. The lock status is the only CC-16 setting that is stored in the
parameter set.