Chapter 6: Program GPI/O and Serial Input/Output
119
Open the GPI tree structure to verify what has been programmed.
Figure 6.6 - Open the tree structure to view what is programmed
All signal processing blocks (except meters) can be invoked by an
external switch in this “snapshot” manner using a GPI in digital mode. You
can also invoke multiple blocks with an external switch in this manner by
dragging multiple blocks into one GPI programming tree.
Invoking a parameter set
Parameter sets can be invoked by an external controller using a GPI in
digital mode. Drag the parameter set into the GPI control panel and drop it
into the desired control input. Drag multiple parameter sets into the GPI to
invoke multiple parameter sets with the same external switch or button.
After dragging the parameter sets into the GPI, choose the appropriate
ON/OFF mode in the Set Mode window.
Invoking a preset
A preset can only be invoked using a timer or a GPI. To invoke a preset
using a GPI, select digital mode, and then drag the preset into the GPI
control panel and drop it into the desired control input.