Chapter 6: Program GPI/O and Serial Input/Output
115
Operating modes
General Purpose Inputs can be configured to operate in one of three
modes: digital, up/down, and analog. Use the Mode buttons in the GPI
control panel to switch a GPI to a different mode.
Operating Mode Description
Digital Typically used when connecting a switch or push button,
this mode expects a normally open switch for operation.
Both “on” and “off” actions are supported
Up/Down Up/Down mode uses two adjacent GPI, and is intended to
support two push buttons for use as volume up and down.
Normally open switches are expected.
Analog Analog mode is intended for a 10K linear type
potentiometer that can be linked to a gain control or
grouped gains. When the potentiometer is at the 10 KOhm
position the gain is set to minimum, and when the pot is at
the 0 KOhm position, the gain is set to the maximum level.