The CC-16 zone controller has an 8-position DIP switch located on the back of the unit. The
DIP switches control addressing and termination settings.
DIP switch addresses
Up to fifteen CC-16s can be connected to an ESP-88 and each must have a unique
address. Use the DIP switches numbered 4, 5, 6 and 7 on the back of the unit to set the
address – 1 through 15. The addresses are in binary format. Refer to the illustration below
to locate binary addresses and the corresponding switch positions.