6
6
pro.Bose.com
O
O
F
F
8
8
FreeSpace
®
DXA 2120
Digital Mixer/Amplifier
TECHNICAL DATA SHEET
Engineers’ and Architects’
Specifications
The unit shall be a digital mixer/amplifier.
The unit shall use a digital signal processing
architecture running at 44.1 kHz sample rate.
The frequency response shall be from 40 Hz to
16 kHz (+0/-3 dB). The dynamic range shall be
80 dB (typical) 40 Hz to 16 kHz. The signal-to-noise
ratio shall be 75 dB or greater (A-weighted).
The unit shall have mixing and routing capabilities
as well as amplification. The unit’s DSP shall
feature selectable Bose
®
loudspeaker EQs as
well as dynamic equalization.
The input section shall have four mic/line inputs,
one direct input and one page input. The mic/line
inputs shall have both 3-pin Euroblock connectors
for balanced mic/line inputs and dual RCA jacks
(summed to mono) for unbalanced line inputs.
The direct and page inputs shall have 4-pin
Euroblock connectors for balanced inputs.
The page input shall be operated in PTT (push
to talk) or Auto mode and provide automatic
ducking for announcements.
The direct input shall automatically override
all other inputs when a signal is detected for
emergency signaling purposes.
The output section shall feature two powered
loudspeaker outputs with 5-terminal inverted
Euroblock connectors. The unit will have an
auxiliary output with a 3-pin Euroblock connector.
The amplifier section shall contain two powered
outputs for high or low impedance: 2 x 120W at
4
or 2 x 100W at 70/100V. The THD shall be
less than 0.5% @ full rated power.
The unit shall feature three different modes of
operation: Mixer Mode, Stereo Select Mode and
Dual Mono Select Mode.
The 100V variant will operate at 100V AC.
A second variant will be able to operate at
120V/220-240V AC; there will be an AC input
voltage switch on the unit. The unit shall
consume AC power of 40W or less at idle,
350W at maximum continuous rated power
and also will have a 2-terminal barrier strip for
connecting a 24V DC backup power supply.
The unit will have a remote input with a
6-pin Euroblock connector for using one or
two volume controls and/or volume control
with A/B select user interfaces.
The unit shall be configurable via the onboard
controls and feature a “lockout” feature to
prevent unwanted system changes. An RS-232
COM port will be available for system updates.
The unit shall be the Bose
®
FreeSpace
®
DXA 2120
digital mixer/amplifier.
Safety and Regulatory Compliance
The 120V/220-240V AC variant (PC 040753,
PC 040754, PC 040755, PC 040756) of the
FreeSpace DXA 2120 digital mixer/amplifier
complies with CE requirements, is UL Listed
according to UL60065 (7th edition) and
CAN/CSA C22.2 No. 60065-03; CB approved,
according to IEC60065 (7th edition), including
group and National differences; GS approved,
according to EN60065 (7th edition). It also
complies with FCC Part 15B Class A (2003),
EN55103-1 (1997), EN55103-2 (1996), and
CISPR13 (2003) requirements.
The 100V variant (PC 040742) of the DXA 2120
digital mixer/amplifier is PSE compliant.
Limited Warranty
The FreeSpace DXA 2120 digital mixer/amplifier
is covered by a two-year transferable limited
warranty.
How our Products are Measured
1. Amplifier power
A single channel is driven to full power
with the nominal load impedance (120W/4,
100W/70V/49
, 100W/100V/98). Output
power is measured using a 1 kHz sine wave
with a THD of less than 0.5%, as measured
at the amplifier output.
2. Dynamic range
The output of the amplifier is connected to
the rated load impedance, and the input and
output gains are set to maximum. A dB-calibrated
voltmeter is connected to the amplifier’s output
through an A-weighting filter (in accordance
with IEC 60651). A 1 kHz signal is connected to
one of the line inputs, and the level is adjusted
to achieve the amplifier’s rated output power.
The voltmeter is then zero-referenced. The
signal source is removed, and the line input is
shorted. The dB-calibrated voltmeter now reads
the absolute dynamic range of the system.