2. Frequency Response of LF Output
A. Apply a 100 mVrms, 80 Hz signal to the
controller's input terminals and reference
your dB meter to this frequency.
B. Measure the frequency response across the
LF outputs according to the chart below.
Frequency (Hz) Response (dB)
20 -10.5 ± 1.5
50 +2.25 ± 1.5
80 REF
100 -7.35 ± 1.5
120 -13.68 ± 1.5
150 -21 ± 1.5
180 -27 ± 1.5
200 -30.5 ± 1.5
3. Protection Circuit Test
NOTE: Refer to Figures 13 through 15 and the
installation instructions for connecting the
external protection circuit harness.
A. Connect a signal generator to the controller
input terminals.
B. Connect the controller LF outputs to the
amplifier input terminals.
C. Connect the external protection circuit harness
to the amplifier output.
D. Connect a voltmeter across the amplifier
output terminals.
E. Apply a 57 Hz signal to the controller input
terminals and adjust the signal generator until the
amplifier's output voltage is 40 Vrms.
F. Increase the input to the amplifier until the
output voltage is 47 Vrms. Continue increasing
the input to the amplifier. The amplifier's output
voltage should not rise above 47 volts
(compression occurs at this voltage).
14